Deckma omd 24

 

SPECIFICATION OMD-24
Range 0 - 30 ppm, Trend up to 50 ppm
Accuracy According IMO MEPC. 107(49)
Linearity Up to 30 ppm better than +/- 2%
Display Graphic Display
Power Supply 24 V AC or DC
Consumption < 5 VA
Alarm Points 1 + 2 Adjustable between 1 - 15 ppm
(Works adjustment 15 ppm)
Alarm 1 Operating Delay
(for annunciator purpose)
Adjustable between 1 - 540 ppm
(Works adjustment 2 sec)
Alarm 2 Operating Delay
(for control purposes)
Adjustable between 1 - 10 ppm
(Works adjustment 10 sec)
System Fault Alarm Red LED
Alarm Contact Rating Potential free 1-pole change over contacts,
3 A / 240 V
Alarm Indication Red LED's
Output Signal 0 - 20 mA or 4 - 20 mA, reversible
ext. Load < 150 Ohm
Sample Water Pressure 0,1 - 10 bar
Sample Flow Approx. 0,1 - 3 l/min, depending to pressure
Ambient Temperature + 1 to +55o C
Sample Water Temperature + 1 to +65o C
Roll Up to 45o C
Size (Computer Unit) 185 mm W X 210 mm H X 65 mm D
Size (Measuring Cell) 140 mm W X 160 mm H X 65 mm D
Degree of Protection IP 65
Weight 5,4 Kgs
Pipe Connections R 1/4 " Female

According to regulations of IMO Resolution MEPC. 107(49)
U.S. Coast Guard approved